Ventilators V8800
Home
/
Ventilation
/
Ventilator
/ Ventilators V8800
Model:
V8800
Ventilation Modes:
Volume Controlled (VCV), Assist /Control
Pressure Controlled (PCV), Assist/Control
Pressure Regulated Volume Controlled (PRVC), Assist/Control
Synchronized Intermittent Mandatory Ventilation,
SIMV(VCV) + PSV, SIMV(PCV) + PSV, SIMV(PRVC) + PSV
Spontaneous Ventilation (SPONT/CPAP) + PSV
Bi Level Ventilation (BIVENT/APRV) + PSV
Non-invasive Ventilation (NIV/CPAP + PSV, NIV/PCV)
Parameters:
Tidal Volume: 20~2500 ml
Respiratory Rate: 1~120 bpm
Inspiration Time: 0.1~12 s
Inspiratory Pause Time: 0~4 s
Tslope: 0~2 s
FiO2: 21%~100%
PEEP: 0~50 cmH2O
CPAP (NIV): 2~20 cmH2O
Psupport: 0~90 cmH2O
Pinsp: 0~100 cmH2O
Phigh: 5~90 cmH2O
Plow: 0~50 cmH2O
Esens: 5%~80%
Flow Patterns: square, decelerating
Inspiratory Hold
Expiratory Hold
Nebulizer: 30 or 45 minutes
Auto Tube Compensation (ATC)
Compliance Compensation
Graphical Trends
Monitoring:
Pressure values: Ppeak, Pmin, Pplat, Pmean, PEEP
Volume/Flow values: Vti, Vte, MV, MVspont, Leak%
Waveforms: Pressure – Time, Flow – Time, Volume – Time
Loops: Flow – Pressure, Pressure – Volume, Volume – Flow
FiO2
Optional EtCO2
Alarms:
MV high, MV low, Circuit disconnect, Paw high, Paw low, Continuous airway pressure high, Vti high, fspont high, Tapnea, FiO2 high, FiO2 low, EtCO2 high, EtCO2 low, Power supply failure, Battery low, Battery exhausted, Air supply failure, O2 supply failure, PEEP low, etc.
Operating Conditions:
Gas Supply: O2, Air, 200~650 kPa (29~94 psi)
Power Supply: 100~240 V, 50/60 Hz
Operating Temperature: 10~40°C
Relative Humidity: 15%~95%, non-condensing
Atmospheric Pressure: 500~1060 hPa
Communication Interfaces: RS-232, VGA, USB, RJ45
Dimensions (H × W × D): 624 x 774 x 1410 mm (with Cart)